Right click on an image and select “Open image in new tab” to expand image!
For more optimization techniques, check out Core Concepts and Physics!
ACR does not currently provide practice parameters for the Mesenteric Duplex Exam. IAC does. This protocol is established following the IAC protocol, ACR principles, and studies demonstrating best practices.The foundational study establishing MAR utilizes the supraceliac aorta (Moneta et al., 1991. Per ACR’s Aorta Practice Parameter, this corresponds to Aorta Prox. Additionally, supraceliac aortic flow and suprarenal flow are physiologically different in healthy and especially unhealthy patients. Therefore, location matters (Moneta et al., 1991; Fleischmann et al., 2001; Endo et al., 2014; Brunsing et al., 2021; Kupinski, 2023; American College of Radiology, n.d.)MALS Evaluation: Compression on Supine deep Expiration, relief when Standing and/or InspirationIn expiration; B-flow shows marked tortuosity and secondary stenotic kink (arrow)Mild compression: meets MALS criteria by some labs; diagnosis verified by vascular surgeon on CT. Note the more distal Prox compression versus Origin: this is a known regular occurrence (Fong et al., 2014; Rege et al., 2021; Kupinski, 2023; Nwaokoro et al., 2026; Maharjan et al., 2026; Radiopaedia, n.d.; Northwestern University Feinberg School of Medicine, 2020).Standing is more diagnostically sensitive than sitting upright only (Downing et al., 2009; Northwestern University Feinberg School of Medicine, 2020; Smereczyński et al., 2021; Kupinski, 2023).